70Kva HL Power Cummins Engine Silent Diesel Generator – Water Cooled with ATS HLDG70S

KSh2,495,000.00KSh3,810,999.00 (-35%)

In stock

???? 70Kva HL Power Cummins Engine Silent Diesel Generator – Water Cooled with ATS ????

Key Features:

  • 70Kva Power Output – Perfect for industrial, commercial, and residential use
  • ???? Automatic Transfer Switch (ATS) – Seamless power changeover during outages
  • ???? Water-Cooled Engine – Reduces overheating for long-lasting performance
  • ???? Silent Operation – Low noise levels, suitable for noise-sensitive environments
  • ????️ Fuel-Efficient Diesel Engine – Low operational costs and high durability

???? Applications:
???? Industrial Sites, ???? Commercial Buildings, ???? Hospitals, ????️ Construction Sites, and ???? Homes

Compare

???? 70Kva HL Power Cummins Engine Silent Diesel Generator – Water Cooled with ATS HLDG70S ????

Stay powered and prepared with the 70Kva HL Power Cummins Engine Silent Diesel Generator – your reliable backup power solution for industrial, commercial, and residential use. This generator features a Cummins Engine, delivering top-tier performance with fuel efficiency and low noise. Equipped with an Automatic Transfer Switch (ATS), this generator ensures seamless switching between the main grid and generator power, keeping your operations running without interruption. ????????

At Macire, we understand how critical consistent power is. That’s why this water-cooled, silent diesel generator is designed for durability, efficiency, and long-term use in even the most demanding environments. ⚡????


???? Key Features

  • ⚡ High Power Output – 70Kva
    Perfect for powering large equipment, heavy-duty machinery, and essential appliances during power outages. Ideal for industrial sites, commercial facilities, and backup power at home.

  • ????️ Fuel-Efficient Cummins Diesel Engine
    Reduces operating costs with optimized fuel consumption while ensuring maximum power delivery.

  • ???? Automatic Transfer Switch (ATS)
    Detects power failure and automatically switches to generator power, then returns to grid power when restored—no manual intervention needed. ????

  • ???? Silent Operation
    Low noise levels at 67.3 dB @ 7 meters, making it suitable for noise-sensitive environments like residential areas and hospitals. ????????

  • ???? Water-Cooled System
    Keeps the engine at optimal temperature for long-lasting performance and reduced wear.

  • ????️ Rugged Design with Anti-Vibration Technology
    Built to withstand demanding conditions with minimal maintenance required.


???? Performance Breakdown – What Can This Generator Power?

The 70Kva Silent Diesel Generator can power multiple appliances and equipment simultaneously. Below is an estimate of its capacity:

Appliance/Equipment Quantity Estimated Hours of Operation
LED Light Bulbs (10W) 100 12+ Hours
Refrigerators (300W) 6 10 Hours
Air Conditioners (2HP) 4 8 Hours
Borehole Pumps (1.5HP) 2 8-10 Hours
Industrial Motors (7.5HP) 2 8 Hours
Security Systems & Fencing Continuous Continuous Operation
Laptops (60W) 20 10+ Hours
Televisions (200W) 8 12+ Hours

???? Application Areas

  • Industrial & Manufacturing Sites ????: Power heavy machinery, compressors, and equipment.
  • Commercial Buildings ????: Keep HVAC systems, lighting, and security running during outages.
  • Hospitals & Clinics ????: Provide backup power for critical medical equipment.
  • Residential Use ????: Ensure uninterrupted power for essential appliances.
  • Construction Sites ????️: Power tools and heavy-duty equipment in remote locations.

????️ Maintenance Tips for Longevity

To keep your Macire 70Kva Generator running at peak performance:

  1. Regularly Check Oil and Coolant Levels – Prevent engine overheating and wear.
  2. Inspect the Air Filter – Clean or replace it to maintain optimal engine efficiency.
  3. Check the Battery and Connections – Ensure proper voltage and clean terminals.
  4. Run the Generator Regularly – Prevent fuel system clogging and keep the engine lubricated.
  5. Use Quality Diesel Fuel – Avoid impurities that can damage the engine.

???? Do’s and Don’ts

✔️ Do:

  • Install in a well-ventilated area.
  • Schedule regular servicing with qualified technicians.
  • Use ATS for automatic switching.

❌ Don’t:

  • Operate with low fuel or without checking oil levels.
  • Ignore unusual engine noises or warning lights.
  • Install in enclosed spaces without proper ventilation.

Frequently Asked Questions (FAQs)

  1. What is the fuel consumption rate?
    Approximately 7.2 liters/hour at full load, depending on usage and load size.

  2. Can this generator run continuously?
    Yes, with proper maintenance. It’s best suited for standby power but can support continuous operations if regularly serviced.

  3. How often should I service the generator?
    Every 250 hours or every 6 months, depending on usage.

  4. Is the generator compatible with solar power systems?
    Yes, it can integrate with solar systems as part of a hybrid power setup.

  5. What is the warranty period?
    The generator comes with a 1-year warranty covering manufacturing defects.


???? Technical Specifications

  • Engine Brand: Cummins
  • Engine Model: LH30DATS3
  • Power Output: 70Kva / 56kW
  • Voltage: 415V
  • Frequency: 50 Hz
  • Fuel Tank Capacity: 100 Liters
  • Fuel Consumption: 7.2 L/h @ 100% load
  • Noise Level: 67.3 dB @ 7 meters
  • Dimensions: 2250 x 1000 x 1200 mm
  • Weight: 1100 kg

Be the first to review “70Kva HL Power Cummins Engine Silent Diesel Generator – Water Cooled with ATS HLDG70S”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Reviews

There are no reviews yet.

See It Styled On Instagram

    No access token
error: Content is protected !!
Let's Chat!

Main Menu

Select at least 2 products
to compare

Macire - Power Solutions & Industrial Equipment!
//
Macire Customer Care
Macire Customer Care
|
//
Can we send you a Free Quote?