3.0kW 4HP Doyin 3-Phase AC Borehole Pump Controller
KSh9,599.00KSh19,990.00 (-52%)
⚡ Power: 3.0kW / 4HP
🔇 Efficiency: Dedicated three-phase motor control
🔁 Automation: AC borehole pump control
🏠 Estates | 🏢 Commercial | 🚜 Farms
🛠 Build: Designed for compatible 4HP three-phase borehole pumps
⭐ Verified & Supported by Macire
3.0kW 4HP Doyin 3-Phase AC Borehole Pump Controller – Three-Phase Control, Motor Protection, Reliable Operation
Product Overview
The 3.0kW 4HP Doyin 3-Phase AC Borehole Pump Controller is specifically designed to control compatible 3.0kW (4HP) three-phase AC borehole pump motors. Its 4HP capacity makes it suitable for more demanding pumping installations where higher motor power is required for borehole water abstraction and transfer.
The controller provides a central electrical interface between the three-phase power supply and the connected pump, supporting controlled starting, operation and shutdown. It is suited to farms, estates, institutions, commercial properties and larger storage-tank filling systems using compatible 4HP three-phase pumps.
Macire verifies controller-to-pump matching before supply and provides technical guidance on cable sizing, three-phase configuration and electrical protection. Correct installation is particularly important with a 3.0kW motor to maintain reliable operation and protect the pumping system.
⭐ Genuine Product | Verified & Supported by Macire
System Architecture & Configuration
Three-Phase AC Control
Designed specifically for three-phase AC borehole pump installations, providing dedicated control of compatible pump motors.
3.0kW / 4HP Motor Matching
Rated for compatible borehole pump motors with a nominal output of 3.0kW (4HP).
Motor Control
Provides a central point for starting, operating and stopping the connected three-phase borehole pump.
Electrical Protection
Correct installation with appropriately rated protection helps safeguard the motor and electrical system against abnormal operating conditions.
Technical Specifications
| Specification | Details |
|---|---|
| Brand | Doyin |
| Product Type | AC Borehole Pump Controller |
| Rated Power | 3.0kW |
| Horsepower | 4HP |
| Power Supply | AC |
| Phase | 3-Phase |
| Motor Compatibility | 3.0kW / 4HP 3-phase pump |
| Primary Function | Borehole pump control |
| Installation | Above-ground control point |
| Recommended Use | Three-phase borehole pumping systems |
Key Features
- Rated for 3.0kW (4HP) borehole pump motors.
- Dedicated three-phase AC pump control.
- Suitable for higher-demand borehole installations.
- Supports controlled motor starting and stopping.
- Centralises electrical control of the pumping system.
- Supports motor protection when correctly installed.
- Suitable for deeper borehole and elevated tank-filling systems.
- Can integrate with compatible automatic water-level controls.
- Suitable for agricultural, institutional and commercial installations.
- Technical pump-to-controller matching available through Macire.
Applications / Use Cases
- 🚜 Farms: Irrigation, livestock water supply and bulk water transfer.
- 🏠 Estates: Higher-demand borehole supply and elevated tank filling.
- 🏢 Commercial Properties: Borehole systems for offices and business facilities.
- 🏥 Institutions: Schools, hospitals and facilities with three-phase power.
- 🏭 Light Commercial Systems: Control of compatible 4HP three-phase pumps.
Installation & Engineering Notes
Connect the controller only to a compatible three-phase AC supply and correctly rated 3.0kW (4HP) three-phase borehole pump motor.
Cable cross-section should be selected according to motor load and total cable length, particularly for deep boreholes where voltage drop can affect motor performance. Appropriate isolation, earthing and upstream circuit protection should be installed.
Three-phase sequence and pump rotation should be verified during commissioning. Macire recommends installation by a qualified electrical or borehole-pump technician.
Care, Maintenance & Operations
- Keep the controller dry and protected from rain.
- Inspect electrical terminals for looseness or overheating.
- Maintain effective system earthing.
- Periodically verify the condition of all three supply phases.
- Check pump cables for deterioration or damage.
- Maintain adequate ventilation around the controller.
- Investigate repeated trips before restarting the pump.
- Use qualified technicians for servicing and electrical repairs.
Do’s & Don’ts
Do’s
- Use with a compatible 3.0kW / 4HP three-phase pump.
- Verify all three phases before commissioning.
- Use correctly sized electrical cables.
- Provide appropriate upstream protection.
- Maintain proper electrical earthing.
- Have installation completed by a qualified technician.
Don’ts
- Do not connect a single-phase pump.
- Do not connect an incorrectly rated motor.
- Do not operate with a missing or abnormal phase.
- Do not bypass protective devices.
- Do not use undersized or damaged cables.
- Do not expose the controller to rain or flooding.
Compatibility
- 3.0kW / 4HP three-phase AC borehole pumps
- Compatible Doyin three-phase submersible pump motors
- Three-phase AC power supplies
- Compatible borehole water-level sensors
- Storage-tank level control systems
- Correctly rated three-phase protection equipment
- Compatible Doyin borehole pump accessories
Performance / Operation Table
| Operating Condition | Controller Role |
|---|---|
| Motor Rating | 3.0kW / 4HP |
| Supply Configuration | Three-Phase AC |
| Pump Start | Controls motor starting |
| Normal Pumping | Maintains pump control |
| Pump Stop | Controls motor shutdown |
| Fault Condition | Protection depends on controller configuration |
Actual operation depends on the connected pump, three-phase supply, cable sizing and installation as guided by Macire.
Mini FAQ
1. What pump rating is this controller designed for?
It is intended for compatible 3.0kW (4HP) three-phase AC borehole pump motors.
2. Is this controller suitable for single-phase pumps?
No. This configuration is specifically intended for three-phase AC pumping systems.
3. Where is a 4HP controller commonly used?
It is suitable for compatible borehole systems serving farms, estates, institutions, commercial facilities and larger storage tanks.
4. Does Macire provide technical installation support?
Yes. Macire provides guidance on controller matching, cable sizing and borehole system configuration.
5. Is nationwide delivery available?
Yes. Macire supports delivery across Kenya.
Why Buy From Macire
- Genuine Doyin pumping equipment.
- Product verification before dispatch.
- Correct controller-to-pump matching.
- Three-phase system configuration guidance.
- Kenya-wide delivery.
- Installation support where applicable.
- Access to compatible Doyin accessories.
- After-sales technical assistance.
- Support for complete borehole pumping solutions.
- Trusted Kenyan supplier of water-pumping equipment.
Short Preview Description











Reviews
There are no reviews yet.