25kVA Pulsar Diesel Silent Generator β Three Phase, 230V/400V, ATS
KSh 722,245.00KSh 960,999.00 (-25%)
β‘ Power: 25 kVA maximum output
???? Silent diesel generator with low noise
???? ATS included for automatic changeover
???? Three Phase | 230V/400V Dual Voltage
???? Commercial | ???? Industrial | ???? Hospitals
???? Heavy-duty diesel industrial engine
β Verified & Supported by Macire
You may also like
-
KSh 279,200.00
KSh 425,995.00 -
KSh 531,245.00
KSh 690,995.00 -
KSh 193,750.00
KSh 276,788.00 -
KSh 198,125.00
KSh 278,000.00
The 25kVA Pulsar Diesel Silent Generator (Three Phase, 230V/400V) is a high-capacity industrial backup power solution designed for demanding commercial and heavy-duty environments across Kenya. With a maximum output of 25kVA, this generator delivers stable three-phase power suitable for factories, large commercial buildings, institutions, and mixed industrial loads.
Built with a heavy-duty diesel engine and a robust brushless alternator, the generator provides consistent voltage output and reliable performance under sustained load. The dual voltage configuration supports both 400V three-phase systems and 230V distribution requirements, ensuring flexibility in complex electrical installations.
The factory-integrated Automatic Transfer Switch (ATS) enables seamless automatic switching during power outages, protecting operations from downtime. Each unit supplied by Macire is verified before dispatch to ensure reliability, safety, and compliance with Kenyan operating conditions.
β Genuine Product | Three Phase 230V/400V | ATS Integrated | Verified & Supported by Macire
System Architecture & Configuration
Engine & Drive System
Heavy-duty diesel engine
Optimised fuel efficiency for industrial loads
Electric start system
Designed for standby and extended commercial operation
Alternator & Power Output
Maximum Output: 25kVA
Three Phase configuration
Voltage: 230V / 400V
Frequency: 50Hz
Stable industrial voltage regulation
Automatic Transfer System
Factory-installed ATS
Automatic mains-to-generator switching
Prevents downtime in critical operations
Suitable for commercial distribution systems
Enclosure & Cooling
Industrial silent canopy
Acoustic insulation for controlled noise levels
Ventilated airflow cooling system
Weather-protected steel enclosure
???? Technical Specifications (Summary)
| Specification | Details |
|---|---|
| Brand | Pulsar |
| Generator Type | Diesel Silent Generator |
| Maximum Power | 25 kVA |
| Phase | Three Phase |
| Voltage | 230V / 400V |
| Frequency | 50Hz |
| Starting Method | Electric Start |
| ATS | Included |
| Cooling Type | Air-cooled |
| Enclosure | Silent canopy |
| Duty Type | Standby / Continuous |
| Warranty | Macire-backed (terms apply) |
???? Key Features
25kVA industrial power output
True three-phase 400V supply
230V support for distribution systems
Factory-integrated ATS
Heavy-duty diesel engine performance
Stable voltage for industrial equipment
Low-noise silent enclosure
Durable steel canopy construction
Suitable for continuous commercial operation
Verified and supported by Macire
???? Applications / Use Cases
???? Industrial production facilities
???? Commercial complexes and office blocks
???? Hospitals and diagnostic centres
???? Hotels and hospitality facilities
???? Construction sites
???? Large farms and agro-processing plants
???? Heavy-duty workshops
???? Installation & Engineering Notes
Install on a firm, level concrete base
Ensure proper ventilation and exhaust clearance
Three-phase wiring must comply with certified standards
Proper earthing is mandatory
ATS connection must be handled by a qualified technician
Macire provides installation guidance and load sizing
???? Care, Maintenance & Operations
Check engine oil levels before operation
Inspect fuel and air filters regularly
Run generator under load periodically
Monitor ATS and electrical terminals
Clean ventilation openings
Service every 6β12 months
Avoid prolonged overload conditions
β οΈ Doβs & Donβts
β Doβs
Operate within rated capacity
Balance loads across phases
Use clean diesel fuel
Follow scheduled maintenance
Ensure adequate ventilation
β Donβts
Do not overload beyond 25kVA
Do not operate without proper earthing
Do not install in enclosed unventilated spaces
Do not ignore abnormal vibration or noise
Do not bypass ATS or safety systems
???? Compatibility Section
Compatible with:
Three-phase commercial and industrial wiring systems
ATS-equipped installations
Industrial machinery and motor-driven equipment
Commercial distribution panels
Macire-supplied stabilisers
Large pumps and HVAC systems
???? Performance / Runtime Guide (Approximate)
| Load % | Approx. Runtime |
|---|---|
| 25% | 12β15 hours |
| 50% | 9β11 hours |
| 75% | 6β8 hours |
| 100% | 4β6 hours |
Actual runtime depends on tank capacity and load profile as guided by Macire.
β Mini FAQ
Q1: Is 25kVA suitable for industrial use?
Yes. It supports heavy three-phase commercial and industrial systems.
Q2: Does it support both 230V and 400V?
Yes. It provides dual voltage 230V/400V output.
Q3: Does it include ATS?
Yes. It comes factory-fitted with Automatic Transfer Switch.
Q4: Is it suitable for continuous operation?
Yes. It is built for standby and extended commercial use.
Q5: Do you deliver nationwide?
Yes. Macire provides Kenya-wide delivery and support.
Macire β Inspired Living. β¨


















Reviews
There are no reviews yet.