22Kva 3Ph Pyramid Water Cooled Silent Diesel Generator with ATS – Blue Heavy Duty Three Phase – Germany Technology

KSh915,995.00KSh1,880,454.00 (-51%)

In stock

Power: 22kVA three phase standby backup output
???? Silent canopy with water cooled diesel performance
???? ATS included for automatic power changeover
???? Homes | ???? Offices | ???? Clinics
???? Heavy-duty build for reliable daily standby use
⭐ Verified & Supported by Macire

Compare

22kVA Pyramid Water Cooled Silent Diesel Generator with ATS – 3 Phase, Silent Canopy, Water Cooled

Product Overview

The 22kVA Pyramid Water Cooled Silent Diesel Generator with ATS is a heavy-duty three phase backup power solution designed for reliable performance in demanding environments. Built with a water cooled diesel engine and enclosed in a silent canopy, it delivers stable power for commercial premises, farms, offices, workshops, and larger residential applications that require dependable standby electricity. The integrated ATS supports automatic changeover during power outages, helping reduce downtime and protect operations.

In the Kenyan market where grid interruptions can affect productivity, cold storage, security systems, pumps, and business continuity, this generator offers a practical and durable backup option. Macire supplies this unit as a verified power solution, helping customers with correct sizing, technical guidance, delivery, and after-sales support. Macire also assists with installation planning and ATS integration for suitable sites.
⭐ Genuine Product | Verified & Supported by Macire

System Architecture & Configuration

Engine / Core System

Powered by a diesel engine with water cooling for improved temperature control, longer operating stability, and better suitability for extended backup use.

Power Output / Performance

Rated at 22kVA, three phase, making it suitable for balanced commercial and light industrial loads, including motors, pumps, lighting, refrigeration, and mixed equipment loads.

Construction / Materials

Heavy-duty steel silent canopy, reinforced base frame, anti-vibration mounting, industrial alternator, and integrated control panel.

Noise / Cooling / Safety

Silent enclosure helps reduce operating noise. Water cooled design supports better thermal management. ATS enables automatic start and transfer during utility failure. Protection systems typically include overload, low oil pressure, high temperature, and short circuit safeguards.

Technical Specifications Table

Specification Details
Rated Power 22kVA
Phase Type 3 Phase
Generator Type Silent diesel generator
Cooling Method Water cooled
Starting System Electric start
ATS Included
Frequency 50Hz
Voltage 415V (three phase typical)
Fuel Type Diesel
Enclosure Type Acoustic / silent canopy
Application Class Standby / backup power
Control Panel Automatic/manual control
Noise Level Low-noise canopy design
Mounting Skid mounted
Protection Features Overload, low oil, high temp, short circuit
Typical Power Factor 0.8
Recommended Use Offices, farms, workshops, light commercial loads
Operating Recommendation Typical operating range recommended by Macire: 50–80% load for best efficiency

Key Features

  • 22kVA three phase output for commercial and mixed-load backup needs
  • Water cooled diesel engine for stable long-run performance
  • Silent canopy design for lower noise operation
  • ATS included for automatic power transfer during outages
  • Heavy-duty frame suitable for demanding environments
  • Reliable standby power for equipment, lighting, and motor loads
  • Electric start for convenient operation
  • Industrial alternator for steady output
  • Protective shutdown systems for safer use
  • Suitable for offices, farms, workshops, and commercial premises
  • Macire support for sizing, supply, and technical guidance
  • Kenya-ready backup solution verified before dispatch by Macire

Applications / Use Cases

  • ???? Large Homes – backup for lighting, water pumps, fridges, freezers, and essential appliances
  • ???? Offices – supports computers, lighting, networking, printers, and security systems
  • ???? Clinics – helps maintain critical lighting, refrigeration, and essential medical support loads
  • ???? Farms – ideal for pumps, electric fencing systems, cold rooms, and processing equipment
  • ???? Workshops – powers tools, compressors, lighting, and workstations
  • ???? Light Commercial Use – suitable for retail spaces, small production units, and service businesses

Installation & Engineering Notes

  • Install on a firm, level, well-ventilated surface.
  • Allow safe clearance around the generator for cooling and servicing.
  • Exhaust routing must direct fumes away from occupied spaces.
  • ATS connection should be handled by a qualified electrician.
  • Proper earthing is required for safe operation.
  • Load balancing across all three phases is important for performance and alternator life.
  • Macire can guide on cabling size, changeover setup, and site suitability.

Care, Maintenance & Operations

  • Check engine oil, coolant, and diesel level before operation.
  • Inspect battery charge and terminal condition regularly.
  • Run the generator periodically even during low outage periods.
  • Service filters, oil, and coolant at recommended intervals.
  • Keep the canopy air paths clean and unobstructed.
  • Avoid prolonged underloading or overloading.
  • Inspect ATS operation during scheduled maintenance.
  • Genuine service parts and support availability through Macire should be maintained where applicable.

Do’s & Don’ts

Do’s

  • Use clean diesel fuel.
  • Keep the unit properly earthed.
  • Balance three phase loads correctly.
  • Service the unit on time.
  • Test ATS functionality regularly.
  • Operate within recommended load range.
  • Follow Macire installation and operating guidance.

Don’ts

  • Do not install in an enclosed unventilated room.
  • Do not overload the generator.
  • Do not ignore low oil or high temperature warnings.
  • Do not refuel while the generator is running.
  • Do not connect loads without proper changeover arrangement.
  • Do not leave the battery weak or discharged for long periods.
  • Do not delay routine maintenance.

Compatibility Section

Compatible with:

  • ATS panels
  • Manual and automatic changeover systems
  • Three phase distribution boards
  • Voltage monitoring and protection systems
  • Water pumps and motor-driven equipment within rating
  • Office and commercial power circuits
  • Selected Macire-supplied accessories for installation and backup power setup

Performance / Runtime Table

Load Level Approx. Load Estimated Runtime Trend*
25% 5.5kVA Lower fuel use, suitable for light backup loads
50% 11kVA Efficient operating zone for regular standby use
75% 16.5kVA Strong performance for mixed commercial demand
100% 22kVA Full rated output for peak standby requirement

*Actual fuel consumption and runtime depend on tank size, site conditions, load balance, maintenance condition, and installation quality as guided by Macire.

Mini FAQ

1. Is 22kVA enough for my business or site?
It is suitable for many offices, workshops, farms, and larger residential backup setups, but final suitability depends on your actual load list. Macire can help size it correctly.

2. Does it come with ATS?
Yes, this version includes ATS for automatic transfer during outages.

3. Can Macire assist with installation?
Yes. Macire can guide on site preparation, ATS integration, and electrical considerations.

4. Is it noisy?
It is designed with a silent canopy, so noise is significantly reduced compared with open-frame generator sets.

5. Do you deliver across Kenya?
Yes. Macire supports supply and delivery arrangements across Kenya, subject to location and order terms.

Why Buy From Macire

  • Genuine products only
  • Product verification before dispatch
  • Technical guidance on correct sizing
  • Support for ATS integration and backup planning
  • Kenya-wide delivery support
  • Trusted local supplier for power solutions
  • Assistance with installation requirements
  • After-sales support and service guidance
  • Access to compatible accessories and system advice
  • Reliable partner for residential, farm, and commercial backup power needs

Be the first to review “22Kva 3Ph Pyramid Water Cooled Silent Diesel Generator with ATS – Blue Heavy Duty Three Phase – Germany Technology”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Reviews

There are no reviews yet.

See It Styled On Instagram

    No access token
error: Content is protected !!
Let's Chat!

Main Menu

Select at least 2 products
to compare

Macire - Power Solutions & Industrial Equipment!
//
Macire Customer Care
Macire Customer Care
|
//
Can we send you a Free Quote?