12kVA MUST Low-Frequency Hybrid Inverter – 48V, 200A, 250VDC

KSh 158,200.00KSh 250,000.00 (-37%)

In stock

⚑ Capacity: 12kVA
βš™οΈ Architecture: Heavy-Duty Low Frequency
πŸ”‹ Battery System: 48V
πŸ”Œ Charging Capacity: 200A
β˜€οΈ PV Input: Up to 250VDC
πŸ”„ Solar | Battery | Utility Integration
🏠 Ideal For: Large Homes | Businesses | Farms | Heavy-Duty Backup
πŸ’™ Supplied & Supported by Macire

Macire – Inspired Living. ✨

The 12kVA MUST Low-Frequency Hybrid Inverter is a heavy-duty power solution designed for solar and backup installations where high load capacity, substantial battery storage and strong charging performance are required. Its low-frequency architecture makes it particularly suited to installations with demanding electrical loads and equipment that can impose significant starting requirements.

Built around a 48V battery system, the inverter can be paired with an appropriately sized battery bank to provide backup power according to the site’s load and required operating duration. The 48V architecture is well suited to a 12kVA system because it supports larger energy-storage configurations required for high-demand applications.

A major feature of this model is its 200A charging capacity. This high charging capability is particularly relevant when the inverter is connected to a substantial battery bank that needs to recover efficiently after discharge. Battery capacity and permitted charging current must, however, be correctly matched to the inverter settings.

The inverter also supports up to 250VDC solar input, allowing a professionally designed PV array to supply renewable energy for battery charging and load support. Solar strings must be configured within the inverter’s permitted operating voltage and current limits.

The combination of 12kVA capacity, low-frequency architecture, 48V battery operation, 200A charging and 250VDC PV input makes this MUST inverter a strong option for large homes, businesses and other sites where a basic high-frequency backup inverter may not be the preferred solution.

Macire can assist with load assessment, battery-bank sizing, solar-array configuration and complete system design before installation.


Technical Specifications

Specification Details
Brand MUST
Product Type Low-Frequency Hybrid Inverter
Rated Capacity 12kVA
Battery Voltage 48VDC
Charging Capacity 200A
PV Input Voltage Up to 250VDC
Inverter Architecture Low Frequency
System Type Hybrid Solar & Backup Power
Energy Sources Solar, Battery & Utility
Battery Configuration 48V Battery Bank
Primary Application Heavy-Duty Solar & Backup Power

Key Features

  • High-capacity 12kVA power platform
  • Heavy-duty low-frequency inverter architecture
  • 48V battery system for substantial energy-storage configurations
  • Powerful 200A charging capacity
  • 250VDC solar input for appropriately configured PV arrays
  • Designed for solar, battery and utility integration
  • Suitable for systems with demanding electrical loads
  • Strong battery-charging capability for larger compatible battery banks
  • Suitable for appropriately matched lithium or lead-acid storage systems
  • Supports extended backup when paired with sufficient battery capacity
  • Designed for professionally engineered residential and commercial power systems

Applications / Use Cases

🏠 Large Residential Homes – suitable for substantial household backup and solar requirements
🏒 Offices – powers appropriately sized ICT, lighting and general office loads
πŸͺ Businesses & Shops – supports essential commercial equipment during outages
🏨 Guesthouses & Lodges – suitable for selected hospitality loads and solar integration
🚜 Farms – useful for appropriately sized farm electrical and backup-power requirements
πŸ”§ Workshops – low-frequency architecture makes it relevant where demanding loads must be considered
β˜€οΈ Solar Systems – integrates PV generation with battery storage
⚑ Longer Backup Systems – supports larger 48V battery banks sized for extended runtime


Installation Notes

  • Complete a professional load assessment before purchasing or installing the inverter
  • Use a correctly configured 48V battery bank
  • Battery capacity must be selected according to actual load and required backup duration
  • Confirm that the selected battery can safely accept the configured charging current
  • The 200A charging setting should not automatically be used at maximum unless the battery manufacturer permits it
  • Configure lithium battery charging according to the battery manufacturer’s requirements
  • Design PV strings within the inverter’s specified 250VDC solar-input limit
  • Calculate PV open-circuit voltage before finalising the solar array
  • Do not exceed the permitted PV voltage or current
  • Use correctly rated PV isolators, DC breakers and surge-protection devices
  • Use appropriately sized battery cables because a 12kVA 48V system can carry substantial DC current
  • Incorporate suitable battery-side isolation and overcurrent protection
  • Correctly size AC input and output cabling
  • Provide proper earthing and surge protection
  • Maintain adequate ventilation around the inverter
  • Installation and commissioning should be carried out by qualified professionals

Care & Maintenance

  • Keep the inverter installation area clean, dry and adequately ventilated
  • Keep cooling vents and airflow paths unobstructed
  • Regularly inspect high-current battery cables and terminals
  • Check battery terminals for looseness, corrosion or abnormal heating
  • Inspect PV cables, connectors, isolators and breakers periodically
  • Monitor battery charging voltage and current
  • Ensure charging settings remain appropriate for the installed battery technology
  • Do not continuously operate the inverter beyond its rated capacity
  • Check the system for warnings, alarms or abnormal operating temperatures
  • Keep electrical protection equipment accessible
  • Arrange professional inspection if repeated overload, charging or battery faults occur
  • Follow MUST operating and maintenance requirements

Mini FAQ

Q1: What capacity is this MUST inverter?
It is a 12kVA low-frequency hybrid inverter intended for larger solar and backup-power installations.

Q2: What battery voltage does it use?
The inverter operates on a 48V battery architecture.

Q3: What is special about the 200A charging capacity?
The 200A charging capability allows the inverter to charge substantial compatible battery storage at a high rate. The actual charging current should always be set according to the battery manufacturer’s permitted charge rate.

Q4: Why choose a low-frequency inverter?
Low-frequency inverter architecture is commonly selected for heavy-duty applications where robust power conversion and demanding load behaviour are important considerations.

Q5: What does 250VDC mean?
It refers to the stated solar PV input voltage capability. The solar panels must be arranged so that the PV string remains within the inverter’s permitted voltage and current range.

Q6: Can it work with lithium batteries?
Yes, provided the lithium battery system is compatible with the inverter’s 48V architecture and the charging parameters are configured correctly.

Q7: How much battery storage should I install?
That depends on the required backup duration and connected load. A 12kVA inverter does not automatically determine battery capacity; Macire can size the battery bank from the site’s actual energy requirements.

Q8: Is this better than a 12kVA high-frequency inverter?
They serve different system requirements. This low-frequency model is particularly relevant where heavy-duty load handling is an important design consideration, while high-frequency models generally offer a more compact architecture.

Q9: Can it run an entire home or business?
Potentially, but this must be determined from the site’s actual simultaneous load, motor starting requirements and battery capacity rather than the 12kVA rating alone.


Why Buy from Macire

  • Genuine MUST solar and backup-power equipment
  • Correct 12kVA low-frequency configuration
  • 48V battery architecture
  • High 200A charging capability
  • 250VDC solar-input configuration
  • Professional load assessment and system sizing
  • Battery-bank sizing based on required runtime
  • Solar PV string configuration support
  • Assistance with compatible lithium battery selection
  • Professional installation and commissioning support
  • Nationwide delivery arrangements
  • Reliable after-sales technical assistance

Order from Macire

Order the 12kVA MUST Low-Frequency Hybrid Inverter for heavy-duty solar and backup-power installations. Macire can assist with load profiling, 48V battery-bank sizing, 250VDC solar-array configuration and protection-system selection to ensure the complete system is correctly engineered for the intended application.

Visit us: Kenafric Business Park, Unit 5, Nairobi, Kenya
WhatsApp: 0750 006 600
Call: 0713 520 969 / 0718 762 530
Website: www.macire.co.ke

Be the first to review “12kVA MUST Low-Frequency Hybrid Inverter – 48V, 200A, 250VDC”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

See It Styled On Instagram

    No access token

Main Menu

Macire - Power Solutions & Industrial Equipment!
//
Macire Customer Care
Macire Customer Care
|
//
Can we send you a Free Quote?