10m³/h 105m Doyin 2HP AC/DC Hybrid Solar Borehole Pump System Kit 4SDS10-1500W AD

KSh 156,829.50KSh 200,000.00 (-22%)

In stock

⚙️ Pump: Doyin 2HP / 1500W AC/DC Hybrid borehole pump
💧 Performance: 10m³/h maximum flow and 105m maximum head
📏 Recommended Depth: Site-specific – confirm through borehole assessment
☀️ Solar Array: 2.36kWp stated – panel quantity requires confirmation
🔌 Kit: 125m submersible cable, 30m PV cable and one splicing kit
💙 Support: Professional selection and sizing guidance from Macire

Macire – Inspired Living. ✨

The 10m³/h 105m Doyin 2HP AC/DC Hybrid Solar Borehole Pump System Kit 4SDS10-1500W AD is a higher-flow solar water-pumping system designed for borehole projects requiring greater water volume while maintaining substantial lifting capability.

Powered by the Doyin 4SDS10-1500W AD 2HP AC/DC Hybrid borehole pump, the system delivers a maximum flow rate of 10m³/h with a maximum head of 105 metres. The 10m³/h flow class makes this configuration particularly relevant for farm water storage, livestock water systems, irrigation storage tanks and higher-demand borehole-to-tank applications.

The package includes 125 metres of 2.5mm² 4-core submersible cable, 30 metres of 6mm² PV cable and one cable-splicing kit. Its AC/DC Hybrid configuration provides a different power-input arrangement from DC-only solar borehole pumps.

Important specification check: the supplied information states 2 × 590W solar panels but also gives a 2.36kWp total PV array capacity. Two 590W panels equal 1.18kWp, not 2.36kWp. A 2.36kWp array would require four 590W panels. This should be confirmed before the final kit configuration is published or supplied.

Actual water output depends on borehole yield, total dynamic head, pipe diameter, delivery distance, available power, solar conditions and installation quality. 10m³/h maximum flow and 105m maximum head represent different operating points and should not be expected simultaneously.

Technical Specifications

Specification Details
Brand Doyin
Model 4SDS10-1500W AD
Product Type AC/DC Hybrid Solar Borehole Pump System Kit
Pump Type AC/DC Hybrid
Motor Power 2HP / 1500W
Maximum Flow Rate 10m³/h
Maximum Head 105m
Solar Panel Rating 590W each
Number of Solar Panels 2 stated – requires confirmation
Total PV Array Capacity 2.36kWp stated – requires confirmation
Submersible Cable 125m, 2.5mm², 4-core
PV Cable 30m, 6mm²
Splicing Kit 1 piece

Kit Contents

  • One Doyin 4SDS10-1500W AD 2HP AC/DC Hybrid borehole pump
  • 590W solar panels – quantity to be confirmed
  • 125m of 2.5mm² 4-core submersible cable
  • 30m of 6mm² PV cable
  • One cable-splicing kit

Key Features

  • 2HP / 1500W Doyin AC/DC Hybrid borehole pump for solar and hybrid water-pumping applications.
  • Higher 10m³/h maximum flow rate for projects requiring increased water transfer capacity.
  • Provides up to 105 metres maximum head.
  • 4SDS10 series configuration combines higher flow capability with substantial pumping head.
  • AC/DC Hybrid design distinguishes this model from DC-only solar pumping systems.
  • Supplied with an extensive 125m of 2.5mm² 4-core submersible cable.
  • Includes 30m of 6mm² PV cable.
  • Supplied with one cable-splicing kit.
  • Particularly relevant for borehole-to-storage applications where daily water volume is an important consideration.
  • Solar-panel quantity and stated 2.36kWp array capacity should be confirmed before installation.

Applications / Use Cases

💧 Higher-Volume Borehole Pumping – the 10m³/h maximum flow makes this model particularly relevant where more water needs to be transferred than with lower-flow 4.5m³/h and 5m³/h pump configurations.

🚜 Farm Water Storage – suitable for pumping borehole water into appropriately sized storage tanks for subsequent farm distribution.

🐄 Livestock Water Systems – useful for filling storage tanks that serve multiple livestock watering points or troughs.

🌱 Irrigation Water Storage – can supply irrigation storage systems where the required flow and total dynamic head match the pump’s operating performance.

🏠 Higher-Demand Water Supply – suitable for appropriately sized residential, institutional or other borehole-to-storage applications requiring greater water transfer.

🏔️ Elevated Tank Filling – the 105m maximum head provides substantial lifting capability where the calculated total dynamic head remains within the pump’s operating range.

🔄 AC/DC Hybrid Pumping – suitable for projects requiring an AC/DC hybrid pump rather than a DC-only solar configuration.

Installation Notes

A professional borehole assessment should be completed before installing the Doyin 4SDS10-1500W AD. Important parameters include borehole depth, static water level, dynamic water level, borehole yield, tank elevation, delivery distance, pipe diameter and required daily water volume.

The specified 105m maximum head is not a recommended installation depth of 105m. No separate recommended installation-depth range was supplied for this kit.

Pump selection should instead be based on total dynamic head (TDH). TDH includes vertical water lift, tank elevation and friction losses through the delivery pipe, valves, bends and fittings.

Solar Array Configuration Check

The supplied figures contain an inconsistency:

2 × 590W = 1,180W = 1.18kWp

Whereas:

4 × 590W = 2,360W = 2.36kWp

Therefore, if 2.36kWp is the intended PV capacity, the system would require four 590W panels, not two. The correct kit configuration should be confirmed before installation.

The final solar-panel electrical arrangement must also comply with the DC input requirements of the 4SDS10-1500W AD.

Because this is an AC/DC Hybrid system, AC and DC connections, protection and operating arrangements should follow the exact Doyin requirements for this model.

The supplied 125m submersible cable should be installed with appropriate support and protection. The submerged connection should be completed using the supplied splicing kit and suitable waterproofing methods.

The 30m of 6mm² PV cable should be properly protected and routed between the solar array and pumping system.

Installation scope, pipework and any additional site-specific components should be confirmed in the final Macire quotation.

Care & Maintenance

  • Keep the solar panels clean, unshaded and securely mounted.
  • Inspect PV connections and mounting structures periodically.
  • Protect the 125m submersible cable against abrasion and physical damage.
  • Inspect the 30m PV cable and accessible electrical connections.
  • Check AC and DC electrical protection periodically.
  • Inspect delivery pipes, fittings and valves for leaks or restrictions.
  • Monitor borehole water levels and avoid pumping below a safe water level.
  • Investigate changes in water output by checking borehole yield, water level, TDH, pipework and available power.
  • Have electrical or pumping faults checked by a qualified technician.
  • Follow Doyin operating and maintenance requirements for the 4SDS10-1500W AD.

Mini FAQ

What is the maximum flow rate?

The Doyin 4SDS10-1500W AD has a maximum flow rate of 10m³/h, making higher water-transfer capacity a key characteristic of this model.

What is the maximum head?

The pump has a maximum head of 105 metres.

Will it deliver 10m³/h at 105m head?

This should not be assumed. 10m³/h maximum flow and 105m maximum head are different operating points. Actual flow at the required head should be confirmed using the applicable pump performance data.

Does 105m head mean the pump should be installed 105m deep?

No. Maximum head and installation depth are different specifications. Correct pump depth should be determined from borehole water levels, borehole yield and total dynamic head.

What power is the pump?

The 4SDS10-1500W AD is specified as a 2HP / 1500W AC/DC Hybrid borehole pump.

How many 590W panels does the kit require?

The supplied information states two 590W panels, but it also states a 2.36kWp total PV array. These figures do not match. Two panels provide 1.18kWp, while four provide 2.36kWp. The intended configuration should therefore be confirmed.

What submersible cable is supplied?

The kit includes 125 metres of 2.5mm² 4-core submersible cable.

How much PV cable is included?

The package includes 30 metres of 6mm² PV cable.

Is a splicing kit included?

Yes. The kit contains one cable-splicing kit.

Is this model suitable for farm water storage?

Yes, where the site’s required water volume and total dynamic head match the pump’s available performance. Its 10m³/h maximum flow makes it particularly relevant for higher-volume borehole-to-storage applications.

Why Buy from Macire

  • Genuine Doyin equipment supplied as an AC/DC hybrid solar pumping package
  • Professional borehole-pump selection and sizing guidance
  • Project-specific solar and water-system design support
  • Transparent equipment and installation quotations
  • Professional installation and commissioning coordination
  • Reliable technical guidance and after-sales support
  • Convenient shopping at Macire’s Nairobi showroom
  • Trusted Kenyan power, machinery and water solutions partner

Order from Macire

Contact Macire for borehole assessment, pump sizing, system selection, ordering and professional installation coordination.

Visit us: Kenafric Business Park, Unit 5, Nairobi, Kenya
WhatsApp: 0750 006 600
Call: 0713 520 969 / 0718 762 530
Website: Macire

Be the first to review “10m³/h 105m Doyin 2HP AC/DC Hybrid Solar Borehole Pump System Kit 4SDS10-1500W AD”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

See It Styled On Instagram

    No access token
Let's Chat!

Main Menu

Macire - Power Solutions & Industrial Equipment!
//
Macire Customer Care
Macire Customer Care
|
//
Can we send you a Free Quote?