Generator Set Specifications
| Minimum Rating | 300 kVA / 240 kW |
| Maximum Rating | 330 kVA / 264 kW |
| Emissions/Fuel Strategy | Fuel Optimised |
| 50 Hz Prime | 300 kVA / 240 kW |
| 50 Hz Standby | 330 kVA / 264 kW |
| Frequency | 50 Hz |
| Speed | 1500 RPM |
| Voltage | 115-415 Volts |
| Minimum Rating | 500 kVA / 400 kW |
| Maximum Rating | 550 kVA / 440 kW |
| Emissions/Fuel Strategy | Fuel Optimised |
| 50 Hz Prime | 500 kVA / 400 kW |
| 50 Hz Standby | 550 kVA / 440 kW |
| Frequency | 50 Hz |
| Speed | 1500 RPM |
| Voltage | 220-415 Volts |
| Engine Model | Perkins 2506A-E15TAG2 |
| Bore | 137 mm (5.4 in) |
| Stroke | 171.0mm (6.7 in) |
| Governor Type | Electronic |
| Displacement | 15.2l (927.6 cu. in) |
| Compression Ratio | 16.0:1 |
| Minimum Rating | 400 kVA / 320 kW |
| Maximum Rating | 450 kVA / 360 kW |
| Emissions/Fuel Strategy | EUIIIa Emissions Compliant |
| 50 Hz Prime | 400 kVA / 320 kW |
| 50 Hz Standby | 450 kVA / 360 kW |
| Frequency | 50 Hz |
| Speed | 1500 RPM |
| Voltage | 220-415 Volts |
⚡ 300kVA Three-Phase Industrial Power
???? Cummins Diesel Engine • Inbuilt ATS
???? Water-Cooled • Reliable Continuous Operation
???? Factories | ???? Hospitals | ???? Commercial Buildings | ☁️ Data Centres
⭐ Verified & Supported by Macire
| Minimum Rating | 313 kVA / 250 kW |
| Maximum Rating | 344 kVA / 275 kW |
| Emissions/Fuel Strategy | Fuel Optimised |
| 60 Hz Prime | 313 kVA / 250 kW |
| 60 Hz Standby | 344 kVA / 275 kW |
| Frequency | 60 Hz |
| Speed | 1800 RPM |
| Voltage | 127-480 Volts |
| Minimum Rating | 300 kVA / 240 kW |
| Maximum Rating | 330 kVA / 264 kW |
| Emissions/Fuel Strategy | Fuel Optimised |
| 50 Hz Prime | 300 kVA / 240 kW |
| 50 Hz Standby | 330 kVA / 264 kW |
| Frequency | 50 Hz |
| Speed | 1500 RPM |
| Voltage | 115-415 Volts |
| Engine Model | Perkins® 1506A-E88TAG5 |
| Bore | 112 mm (4.4 in) |
| Stroke | 149 mm (5.9 in) |
| Governor Type | Electronic |
| Displacement | 8.8l (537 cu. in) |
| Compression Ratio | 16.1:1 |
⚡ 250kVA Three-Phase Industrial Power
???? Genuine Cummins Engine • Inbuilt ATS
???? Water-Cooled • Silent Canopy • Built for Continuous Operation
???? Factories | ???? Hospitals | ???? Hotels | ☁️ Data Centres
⭐ Verified & Supported by Macire
| Minimum Rating | 250 kVA / 200 kW |
| Maximum Rating | 275 kVA / 220 kW |
| Emissions/Fuel Strategy | Fuel Optimised |
| 50 Hz Prime | 250 kVA / 200 kW |
| 50 Hz Standby | 275 kVA / 220 kW |
| Frequency | 50 Hz |
| Speed | 1500 RPM |
| Voltage | 115-415 Volts |
⚡ 200kVA Three-Phase Industrial Power
???? Genuine Cummins Engine • Inbuilt ATS
???? Water-Cooled • Silent Canopy • Built for Continuous Operation
???? Factories | ???? Hospitals | ???? Hotels | ☁️ Data Centres
⭐ Verified & Supported by Macire
⚡ Power Output: 100kVA backup power
???? Water-cooled diesel engine
???? ATS-ready automatic backup support
???? Offices | ???? Industrial | ???? Institutions
???? Silent heavy-duty canopy design
⭐ Verified & Supported by Macire
| Minimum Rating | 180 kVA / 144 kW |
| Maximum Rating | 200 kVA / 160 kW |
| Emissions/Fuel Strategy | EU Stage IIIA emissions compliant. |
| 50 Hz Prime | 180 kVA / 144 kW |
| 50 Hz Standby | 200 kVA / 160 kW |
| Frequency | 50 Hz |
| Speed | 1500 RPM |
| Voltage | 220-415 Volts |
???? 150Kva HL Power Cummins Engine Silent Diesel Generator – Water Cooled with ATS HLDG150S ????
Key Features:
???? Applications: ???? Industrial Sites, ???? Commercial Buildings, ???? Hospitals, ????️ Construction Sites, ???? Homes
| Minimum Rating | 150 kVA / 120 kW |
| Maximum Rating | 187.5 kVA / 150 kW |
| Emissions/Fuel Strategy | Fuel Optimised |
| 50 Hz Prime | 150 kVA / 120 kW |
| 50 Hz Standby | 165 kVA / 132 kW |
| 60 Hz Prime | 168.8 kVA / 135 kW |
| 60 Hz Standby | 187.5 kVA / 150 kW |
| Frequency | 50 / 60 Hz |
| Speed | 1500 or 1800 RPM |
| Voltage | 110-480 Volts |
| 50 Hz Prime Rating | These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. |
| 60 Hz Prime Rating | These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). |
| 50 Hz Standby Rating | Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. |
| Engine Model | Perkins® 1106A-70TAG2 |
| Bore | 105 mm (4.1 in) |
| Stroke | 135 mm (5.3 in) |
| Governor Type | Mechanical |
| Displacement | 7.0l (427.8 cu. in) |
| Compression Ratio | 16.0:1 |
Petrol & Diesel Power Generators
Our range of Petrol & Diesel Power Generators delivers dependable backup and prime power solutions for homes, businesses, construction sites, farms, and institutions across Kenya. Designed for reliability and performance, these generators provide stable electricity during outages, remote operations, and high-demand applications where grid power is unreliable or unavailable.
Macire supplies silent diesel generators, portable petrol generators, and heavy-duty industrial sets suited for residential, commercial, and industrial use. Whether you need a compact generator for home essentials, a mid-range unit for offices and shops, or a robust diesel generator for continuous operation, we offer solutions built for durability, fuel efficiency, and long service life.
Our generator solutions can be paired with Automatic Transfer Switches (ATS), solar hybrid systems, and professional installation support, ensuring seamless power continuity. Backed by expert advice, genuine products, and after-sales support, Macire helps you stay powered — anytime, anywhere.
Macire – Inspired Living.